Changes between Version 6 and Version 7 of WikiStart


Ignore:
Timestamp:
Mar 17, 2017, 11:01:45 AM (7 years ago)
Author:
bouyer
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • WikiStart

    v6 v7  
    3535
    3636For each tension or current range, we take 8 samples between 0 and a value
    37 close to the max of the range. For each sample we get the pic's output for
    38 about 5 seconds, and we note the real value using the digital multimeter.
     37close to the max of the range. For each sample we get a few tousand values from pic's output, while we note the real value using the digital multimeter.
    3938
    4039From this process, we found that that the AD623 output can't go down to 0,
     
    4544we have a +/-7 unit error on the ADC's output. This is less than 0.18% of the
    4645full range (or +/- 4.4mA on the 2.45A range input).
     46
     47[[Image(0mA.gif, 50%, title="ADC values for 0mA",longdesc="ADC values for 0mA")]]