    4545full range (or +/- 4.4mA on the 2.45A range input). Below are plots for measures on the 0.61A scale.
    4646
    47 [[Image(0mA.gif, 50%, align=left, title="ADC values for 0mA",longdesc="ADC values for 0mA")]] [[Image(536.7mA.gif, 50%, align=right, title="ADC values for 536.7mA",longdesc="ADC values for 536.7mA")]]
     47[[Image(0mA.gif, 50%, align=left, title="ADC values for 0mA",longdesc="ADC values for 0mA")]]
     48[[Image(536.7mA.gif, 50%, align=right, title="ADC values for 536.7mA",longdesc="ADC values for 536.7mA")]]
     49
     50From the 536.7mA measure we have a 8% error for the ADC's output (we expect 3559, we get 3851). We can use this to correct our convertion ratio:
     51adc(i)=3851/536.7 * i (with i in mA). With this conversion function, and
     52excluding the value at 0mA, the error with the measured ADC output is
     53at most 4, which is within the noise.
     54[[Image(i_o.gif, 50%, align=right, title="current to ADC outut",longdesc="current to ADC output")]]